Depth...........................................500 mm
Width............................................950 mm
Height........................................1340 mm
Total weight................................230 kg.
Vacuum Pump:
Designed for continuous work, it has a winged carter with oil meter display and an automatic vacuum and oil retention valve. Propelling gases are filtered with long life coalescent elements (renewable). Low noise level.
Electronic board:
It commands the pneumatic sequence operations that comprise the work cycle to attain an optimal automation. To this effect, it has a Programmable Controller, which has logical functions, counters, temporizers and other special features that allow the make up of a program that matches the machine’s complexity.
In the following table are detailed approximate load time values for
different sizes of fire extinguishers:
| Capacity |
Load Time |
| 1 kg. |
6 – 8 sec. |
| 2,5 kg. |
8 – 9 sec. |
| 5 kg. |
9 – 11 sec. |
| 10 kg. |
12 – 14 sec. |
| 12 kg. |
14 – 16 sec. |
Electrical feed:
3x380 V 50 Hz / 3x220V 60 Hz
Requiered air pressure:
5 a 6 bar
Vacuum Pump:
2 HP Power Gauge 66 m3/h
|
|